11. Specifications
Electrical
Power Supply: External regulated DC adapter, included. Region-specific plug type (US, UK, EU, or AU) based on shipping destination.
DC Input to Unit: 5v
Switched Outlet Load Rating: See https://dlidirect.com/products/iot-power-relay for details.
Outlet Configuration: Four AC outlets total. Two normally-off (switched on by relay), one normally-on (switched off by relay), and one always-on (unswitched). Outlet type matches destination region.
Timing
Base Time Range: 0.1 to 99.9 seconds
Base Time Resolution: 0.1 seconds
Timing Accuracy: ±0.05 seconds
Test Interval Settings: 1/8, 1/4, 1/3, 1/2 stop
Print Stop Select Range: -3 to +3 stops, in whole-stop increments
Memory
Program Memory Banks: 3
Stored per Bank: Base Time, Test Interval, Print Stop Select
Retention: Persistent across power cycles
Connections
DC Power Input: 5.5 x 2.5mm Jack
Enlarger Relay Jack: 3.5mm TRS
Footswitch Jack: 3.5mm TRS
What's Not Included in Specifications
The ΔStop 100 is designed to be compatible with the majority of standard darkroom enlargers, but enlarger compatibility depends on the specific enlarger model rather than the ΔStop's specifications alone. See Section 3 for compatibility guidance and the project page at deltastoptimer.com for a current compatibility list.